In a reverse-osmosis (RO) system, water passes through the membrane and salts are left behind in the concentrate. As the concentrate gets stronger, sparingly soluble salts such as calcium carbonate, calcium sulfate or silica can crystallise on the membrane surface. This is scaling, and it lowers output and raises pressure and energy use.

An antiscalant is dosed into the feed water to delay this crystallisation. Different products are designed for different scaling risks, so choose one using a full feed water analysis and your recovery rate, not only the price per litre. Check that the antiscalant is compatible with your membranes and is approved for your use, for example for drinking water.

Even with good pretreatment, membranes eventually foul with scale, organic matter, biological growth or colloids. Cleaning is needed when output falls, differential pressure rises or salt passage increases, ideally before the changes become large.

Membrane cleaners are usually sold in two types. Acidic cleaners dissolve mineral scale and metal oxides, and alkaline cleaners remove organic and biological fouling. Which to use first depends on the type of deposit, so identify it where possible.

Always follow the membrane manufacturer's limits for pH, temperature and contact time, rinse thoroughly, and never mix cleaning chemicals. Keep records of flow, pressure and conductivity, because they show early what the system needs.