Two documents come with most chemical shipments. The Certificate of Analysis (COA) describes one specific batch. The Safety Data Sheet (SDS) describes the product in general and how to handle it.
On a COA, first check that the product name, batch or lot number and manufacturing date match what is on your packaging. Then read the table of tests: each parameter, the test method, the specification limit and the measured result. The result must fall within the limit.
Check that the specification and standard named on the COA are the ones you ordered. Look for the purity or assay, water content and the impurities that matter for your use. A COA that gives only a general statement such as "conforms" without values tells you much less.
An SDS has 16 sections in a standard order. The most useful ones for daily work are identification (section 1), hazards (2), first aid (4), firefighting (5), handling and storage (7), exposure controls and protective equipment (8), and disposal (13).
Keep both documents with the batch records. Make sure the SDS is current and available in a language your staff understand, and tell your supplier at once if the COA and your own tests disagree.